Recent Updates
SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added 3 new photos in IDEC
Nov 6, 2026 at 01:48 pm —
SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added 2 new photos in SIEMENS - SIEMENS LOW VOLTAGE
Nov 6, 2026 at 11:06 am —
SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added 2 new photos in REXROTH
Nov 6, 2026 at 10:53 am —
SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added new photo in SCHNEIDER - SCHNEIDER LOW VOLTAGE
Nov 5, 2026 at 03:39 pm —
Schneider LADN22 Auxiliary Contact Block Malaysia
Specifications Main Range TeSys TeSys Deca Product name TeSys Deca Product or component type Auxiliary contact block Device short name LADN Range compatibility TeSys D CAD TeSys D LC1D TeSys F LC1F TeSys F CR1F TeSys Deca CAD TeSys Deca LC1D Mounting location Front Pole contact composition 2 NO + 2 NC Contacts operation Instantaneous [Ue] rated operational voltage 690 V AC 25...400 Hz [Ie] rated operational current 6 A at 120 V AC-15 1.04 A at 690 V AC-15 0.55 A at 125 V DC-13 0.1 A at 600 V DC-13 [Ui] rated insulation voltage 690 V conforming to IEC 60947-5-1 600 V conforming to UL 600 V conforming to CSA [Ith] conventional free air thermal current 10 A (at 60 ˇăC) Standards EN/IEC 60947-5-1 GB/T 14048.5 EN 50012 UL 60947-5-1 CSA C22.2 No 60947-5-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ Product certifications CB Scheme UL CSA CCC EAC UKCA Complementary Irms rated making capacity 140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1 Permissible short-time rating 100 A 60 ˇăC 1 s 120 A 60 ˇăC 500 ms 140 A 60 ˇăC 100 ms Protection type GG fuse 10 A Mechanical durability 30 Mcycles Minimum switching current 5 mA Minimum switching voltage 17 V Non-overlap time 1.5 ms on de-energisation no overlap between NC and NO contact 1.5 ms on energisation no overlap between NC and NO contact Insulation resistance > 10 MOhm Connections - terminals Screw clamp terminals 1 cable(s) 1ˇ4 mm²flexible with cable end Screw clamp terminals 1 cable(s) 1ˇ4 mm²flexible without cable end Screw clamp terminals 2 cable(s) 1ˇ2.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 1ˇ4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 1ˇ4 mm²rigid without cable end Screw clamp terminals 2 cable(s) 1ˇ4 mm²rigid without cable end Tightening torque 1.7 N.m - with screwdriver flat Ø 6 mm 1.7 N.m - with screwdriver Philips No 2 1.7 N.m - with screwdriver pozidriv No 2 Height 48 mm Width 44 mm Depth 42 mm Net weight 0.05 kg Colour Dark grey read more
SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added new photo in SIEMENS - SIMATIC S7
Nov 5, 2026 at 03:20 pm —
Siemens 6ES7954-8LE04-0AA0 SIMATIC S7 Memory Card Malaysia
Specifications Commercial data Technical data Product related Article number 6ES7954-8LE04-0AA0 Life cycle status Active Product Product Family SIPLUS CPU 1518-3 PN EAN 4047623411956 UPC 195125441576 Commodity Code 85235110 Pricing related Customer Price – List Price – Region Specific Price Group / Headquarter Price Group 212 / 212 Surcharge for raw material – Metal Factor – Delivery related Export Control Regulations AL : N / ECCN : N Standard delivery time 50 Day/Days Packaging dimensions (L x W x H) 11,5 x 9,2 x 0,32 cm Net weight 0,017 Kg Quantity Unit 1 Piece Packaging Quantity 1 Minimum Order Quantity 1 Dangerous goods No Environment related WEEE (2012/19/EU) Take-Back Obligations 5 Compliance with the substance restrictions according to RoHS directive Since: 16.02.2023 REACH Art. 33 Duty to inform according to the current list of candidates Reach Information SCIP Number not available Siemens specific Product Group 4507 Catalog ID ST72 Group Code RL02 Country of origin Germany read more
SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added new photo in ABB - ABB LOW VOLTAGE
Nov 5, 2026 at 02:49 pm —
ABB PSR16-600-70 Softstarter Malaysia
Technical Rated Operational Voltage: 208 ... 600 V AC Rated Control Supply Voltage (Us): 100 ... 240 V AC Rated Control Circuit Voltage (Uc): 24 V DC Rated Frequency (f): 50/60 Hz Main Circuit 50 / 60 Hz Rated Operational Power - In-Line Connection (Pe): (230 V) 4 kW (400 V) 7.5 kW (500 V) 7.5 kW Rated Operational Current - In-Line Connection (Ie): 16 A Service Factor Percentage: 100 % Overload Protection: Recommended MS132 10.00 ... 16.00 Integrated Electronic Overload: No Starting Capacity at Maximum Rated Current Ie: 4xIe for 6s Ramp Time: 0 ... 20 s 1 ... 10 s Initial Voltage During Start: 40 ... 70 % Step Down Voltage Special Ramp: 100 ... 60 % Current Limit Function: No Switch for Inside Delta Connection: No Run Signal Relay: Yes By-pass Signal Relay: No Fault Signal Relay: No Overload Signal Relay: No Signal Indication Completed Start Ramp (LED): Green Signal Indication Ready to Start/Standby ON (LED): Green Signal Indication Running R (LED): Green Signal Indication Ramping Up/Down (LED): Green Number of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time: 10 Communication: FiledBusPlug(Optional) Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 Terminal Type: Screw Terminals Connecting Capacity Main Circuit: Rigid 1/2 x 0.75 ... 2.5 mm² Connecting Capacity Control Circuit: 1 x 0.75 ... 2.5 mm² 2 x 0.75 ... 2.5 mm² Rigid 1/2 x 0.75 ... 2.5 mm² Connecting Capacity Supply Circuit: Rigid 1/2 x 0.75 ... 2.5 Tightening Torque: Control Circuit 1 N·m Main Circuit 1 N·m Supply Circuit 1 N·m Product Main Type: PSR16 Function: Soft start with voltage ramp Soft stop with voltage ramp Technical UL/CSA Horsepower Rating UL/CSA: (200 ... 208 V AC) Three Phase 3 Hp (220 ... 240 V AC) Three Phase 5 Hp (440 ... 480 V AC) Three Phase 10 Hp (550 ... 600 V AC) Three Phase 10 Hp Maximum Operating Voltage UL/CSA: Main Circuit 600 V Tightening Torque UL/CSA: Control Circuit 8.9 in·lb Main Circuit 8.9 Supply Circuit 8.9 in·lb read more
SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added new photo in ABB - ABB LOW VOLTAGE
Nov 5, 2026 at 12:31 pm —
ABB PSR30-600-70 Softstarter Malaysia
Technical Rated Operational Voltage: 208 ... 600 V AC Rated Control Supply Voltage (Us): 100 ... 240 V AC Rated Control Circuit Voltage (Uc): 24 V DC Rated Frequency (f): 50/60 Hz Main Circuit 50 / 60 Hz Rated Operational Power - In-Line Connection (Pe): (230 V) 7.5 kW (400 V) 15 kW (500 V) 18.5 kW Rated Operational Current - In-Line Connection (Ie): 30 A Service Factor Percentage: 100 % Overload Protection: Recommended MS132 25 ... 32 Integrated Electronic Overload: No Starting Capacity at Maximum Rated Current Ie: 4xIe for 6s Ramp Time: 0 ... 20 s 1 ... 10 s Initial Voltage During Start: 40 ... 70 % Step Down Voltage Special Ramp: 100 ... 60 % Current Limit Function: No Switch for Inside Delta Connection: No Run Signal Relay: Yes By-pass Signal Relay: Yes Fault Signal Relay: No Overload Signal Relay: No Signal Indication Completed Start Ramp (LED): Green Signal Indication Ready to Start/Standby ON (LED): Green Signal Indication Running R (LED): Green Signal Indication Ramping Up/Down (LED): Green Number of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time: 10 Communication: FiledBusPlug(Optional) Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 Terminal Type: Screw Terminals Connecting Capacity Main Circuit: Rigid 1/2 x 2.5 ... 10 mm² Connecting Capacity Control Circuit: 1 x 0.75 ... 2.5 mm² 2 x 0.75 ... 2.5 mm² Rigid 1 x 0.75 ... 2.5 mm² Rigid 2 x 0.75 ... 1.5 mm² Connecting Capacity Supply Circuit: Rigid 1 x 0.75 ... 2.5 Tightening Torque: Control Circuit 0.6 N·m Main Circuit 2.3 N·m Supply Circuit 0.6 N·m Product Main Type: PSR30 Function: Soft start with voltage ramp Soft stop with voltage ramp Technical UL/CSA Horsepower Rating UL/CSA: (200 ... 208 V AC) Three Phase 7.5 Hp (220 ... 240 V AC) Three Phase 10 Hp (440 ... 480 V AC) Three Phase 20 Hp (550 ... 600 V AC) Three Phase 25 Hp Maximum Operating Voltage UL/CSA: Main Circuit 600 V Tightening Torque UL/CSA: Control Circuit 5.3 in·lb Main Circuit 20.4 Supply Circuit 5.3 in·lb read more
SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added new photo in SCHNEIDER - SPEED DRIVES
Nov 5, 2026 at 12:23 pm —
Schneider ATV320U15N4C Variable Speed Drive Malaysia
Specifications Main Range of product Altivar Machine ATV320 Product or component type Variable speed drive Product specific application Complex machines Variant Standard version Format of the drive Compact Mounting mode Wall mount Communication port protocol Modbus serial CANopen Option card Communication module, CANopen Communication module, EtherCAT Communication module, Profibus DP V1 Communication module, PROFINET Communication module, Ethernet Powerlink Communication module, EtherNet/IP Communication module, DeviceNet [Us] rated supply voltage 380...500 V - 15...10 % nominal output current 4.1 A Motor power kW 1.5 kW for heavy duty Motor power hp 2 hp EMC filter Class C2 EMC filter integrated IP degree of protection IP20 Complementary Discrete input number 7 Discrete input type STO safe torque off, 24 V DC, impedance: 1.5 kOhm DI1...DI6 logic inputs, 24 V DC (30 V) DI5 programmable as pulse input: 0ˇ30 kHz, 24 V DC (30 V) Discrete input logic Positive logic (source) Negative logic (sink) Discrete output number 3 Discrete output type Open collector DQ+ 0ˇ1 kHz 30 V DC 100 mA Open collector DQ- 0ˇ1 kHz 30 V DC 100 mA Analogue input number 3 Analogue input type AI1 voltage: 0...10 V DC, impedance: 30 kOhm, resolution 10 bits AI2 bipolar differential voltage: +/- 10 V DC, impedance: 30 kOhm, resolution 10 bits AI3 current: 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 10 bits Analogue output number 1 Analogue output type Software-configurable current AQ1: 0...20 mA impedance 800 Ohm, resolution 10 bits Software-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bits Relay output type Configurable relay logic R1A 1 NO electrical durability 100000 cycles Configurable relay logic R1B 1 NC electrical durability 100000 cycles Configurable relay logic R1C Configurable relay logic R2A 1 NO electrical durability 100000 cycles Configurable relay logic R2C Maximum switching current Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 250 V AC Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 30 V DC Minimum switching current Relay output R1A, R1B, R1C, R2A, R2C: 5 mA at 24 V DC Method of access Slave CANopen 4 quadrant operation possible True Asynchronous motor control profile Voltage/frequency ratio, 5 points Flux vector control without sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor - Energy Saving Voltage/frequency ratio, 2 points Synchronous motor control profile Vector control without sensor Maximum output frequency 0.599 kHz Acceleration and deceleration ramps Linear U S CUS Ramp switching Acceleration/deceleration ramp adaptation Acceleration/deceleration automatic stop with DC injection Motor slip compensation Automatic whatever the load Adjustable 0...300 % Not available in voltage/frequency ratio (2 or 5 points) Switching frequency 2...16 kHz adjustable 4...16 kHz with derating factor Nominal switching frequency 4 kHz Braking to standstill By DC injection Brake chopper integrated True Line current 6.4 A at 380 V (heavy duty) 4.9 A at 500 V (heavy duty) Maximum input current 6.4 A Maximum output voltage 500 V Apparent power 4.2 kVA at 500 V (heavy duty) Network frequency 50...60 Hz Relative symmetric network frequency tolerance 5 % Prospective line Isc 5 kA Base load current at high overload 3.0 A Power dissipation in W Fan: 56.0 W at 380 V, switching frequency 4 kHz With safety function Safely Limited Speed (SLS) True With safety function Safe brake management (SBC/SBT) False With safety function Safe Operating Stop (SOS) False With safety function Safe Position (SP) False With safety function Safe programmable logic False With safety function Safe Speed Monitor (SSM) False With safety function Safe Stop 1 (SS1) True With sft fct Safe Stop 2 (SS2) False With safety function Safe torque off (STO) True With safety function Safely Limited Position (SLP) False With safety function Safe Direction (SDI) False Protection type Input phase breaks: drive Overcurrent between output phases and earth: drive Overheating protection: drive Short-circuit between motor phases: drive Thermal protection: drive Width 105.0 mm Height 142.0 mm Depth 158.0 mm Net weight 1.3 kg Transient overtorque 170ˇ200 % of nominal motor torque read more
SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added new photo in PILZ
Nov 5, 2026 at 12:16 pm —
SJT SUCCESS INDUSTRIAL AUTOMATION SDN. BHD. added new photo in SIEMENS - SIEMENS LOW VOLTAGE
Nov 3, 2026 at 05:02 pm —
Siemens 3RV2901-1D Auxiliary Switch Transverse Malaysia
Specifications Commercial data Technical data Product related Article number 3RV2901-1D Life cycle status Active Product Product Family Mountable accessories EAN 4011209790940 UPC 662643924725 Commodity Code 85365080 Pricing related Customer Price – List Price – Region Specific Price Group / Headquarter Price Group 1D / 41E Surcharge for raw material – Metal Factor LBP----- Delivery related Export Control Regulations AL : N / ECCN : N Standard delivery time 5 Day/Days Packaging dimensions (L x W x H) 45.00 x 35.00 x 12.00 mm Net weight 0.016 Kg Quantity Unit 1 pc. Packaging Quantity 1 Minimum Order Quantity 1 Dangerous goods No Environment related WEEE (2012/19/EU) Take-Back Obligations 5 Compliance with the substance restrictions according to RoHS directive Since: 01/10/09 REACH Art. 33 Duty to inform according to the current list of candidates Reach Information SCIP Number not available Siemens specific Product Group 5335 Catalog ID CC-IC10 Group Code R711 Country of origin Romania read more















